Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 31
Filtrar
1.
EFORT Open Rev ; 8(7): 499-508, 2023 Jul 03.
Artigo em Inglês | MEDLINE | ID: mdl-37395678

RESUMO

The objectives of the 1st EFORT European Consensus on 'Medical and Scientific Research Requirements for the Clinical Introduction of Artificial Joint Arthroplasty Devices' were foremost to focus on patient safety by establishing performance requirements for medical devices. The 1st EFORT European Consensus applied an a priori-defined, modified Delphi methodology to produce unbiased, high-quality recommendation statements, confirmed by consensus voting of a European expert panel. Intended key outcomes are practical guidelines justified by the current stage of knowledge and based on a broad European Expert Consensus, to maintain innovation and optimisation of orthopaedic devices within the boundaries of MDR 2017/745. Twenty-one main research areas of relevance were defined relying on input from the EFORT IPSI WG1 'Introduction of Innovation' recommendations and a related survey. A modified Delphi approach with a preparatory literature review and work in small groups were used to prepare answers to the research questions in the form of 32 draft Consensus statements. A Consensus Conference in a hybrid format, on-site in the Carl Gustav Carus University of Dresden was organised to further refine the draft statements and define consensus within the complete group of participants by final voting, intended to further quantify expert opinion knowledge. The modified Delphi approach provides practical guidelines for hands-on orientation for orthopaedic surgeons, research institutes and laboratories, orthopaedic device manufacturers, patient representatives, Notified Bodies, National Institutes and authorities. For the first time, initiated by the EFORT IPSI (WG1 'Introduction of Innovation'), knowledge of all related stakeholders was combined in the 1st EFORT European Consensus to develop guidelines and result in a comprehensive set of recommendations.

2.
Biomed Res Int ; 2022: 5738610, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36132080

RESUMO

End-of-stem pain of the femur is a common problem in revision total knee arthroplasty (TKA). It may be caused by a problematic interaction between stem and bone, but the exact biomechanical correlate is still unknown. The aim of this prospective study was to find out how the stem is positioned in the medullary canal, how the femoral geometry changes due to implantation, and whether the results are influenced by the diameter of the trial. We implanted 16 rotating hinge knee implants into 16 fresh-frozen human femora using the hybrid fixation technique and comparing two reaming protocols. We created 3-dimensional models of the specimens before and after implantation using CT-scans and calculated the differences. The main contact between stem and bone was found at the proximal 30 mm of the stem, especially anterior. We observed two different contact patterns of stem and bone. The cortical thickness was reduced especially at the anterior tip of the stem with a maximum reduction of 1405 ± 501 µm in the standard group and 980 ± 447 µm in the small_trial group, which is a relative reduction of 34 ± 14% (standard group) and 26 ± 14% (small_trial group). The bone experienced a deformation to posterior and lateral. We conclude that the tip of the stem is an important biomechanical region. Different contact patterns between stem and bone as well as the reduction in cortical thickness at the tip of the stem may play a role in the development of end-of-stem pain.


Assuntos
Artroplastia do Joelho , Prótese do Joelho , Artroplastia do Joelho/métodos , Fenômenos Biomecânicos , Fêmur/diagnóstico por imagem , Fêmur/cirurgia , Humanos , Dor/cirurgia , Estudos Prospectivos , Desenho de Prótese , Tomografia Computadorizada por Raios X
3.
Front Bioeng Biotechnol ; 10: 845859, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35356773

RESUMO

Background: The use of rotating hinge (RH) prostheses for severe primary as well as revision arthroplasty is widely established. Due to the steadily increasing number of RH prostheses, we aimed to assess the complication frequencies, complication types and clinical outcomes of a modern RH hinge prosthesis using a new bearing material with a minimum follow-up of 7 years. Methods: Fifty-six consecutive patients who received the EnduRo® RH prosthesis using carbon-fiber reinforced poly-ether-ether-ketone (CFR-PEEK) as bearing material were included in this prospective study: 21 patients (37.5%) received the prosthesis as a primary total knee arthroplasty (TKA) and 35 patients (62.5%) underwent revision total knee arthroplasties (rTKA). Clinical and radiographic examinations were performed preoperatively, postoperatively after three and 12 months and annually thereafter. Clinical scores were documented for each patient. Competing risk analysis was assessed with respect to indication and failure mode. Results: Knee Society Score (KSS), Western Ontario and McMaster Osteoarthritis Index (WOMAC), Oxford Knee Score (OKS) and range of motion (ROM) improved significantly compared to preoperative values (p < 0.0001). The overall cumulative incidence for revision surgery was 23.6% at 7 years and the cumulative incidence for complications associated with failure of the prothesis was 5.6% at 7 years, respectively. Complications occurred more frequently in the revision group (p = 0.002). Conclusion: The evaluated RH prosthesis provided reliable and durable results for a minimum follow-up of 7 years. Prosthesis survival was successful considering the complexity of the cases. The use of this RH system in primary patients showed high survival rates and long-term functional outcomes and clinical outcomes proved to be satisfying in both revision and primary cases. No adverse events were associated with the new bearing material CFR-PEEK.

4.
J Arthroplasty ; 36(8): 2871-2877, 2021 08.
Artigo em Inglês | MEDLINE | ID: mdl-33812711

RESUMO

BACKGROUND: Metal-on-metal (MOM) surfaces in total hip arthroplasty (THA) have been used widely. Serum cobalt and chromium levels have been the standard investigation for follow-up examinations, but magnetic resonance imaging (MRI) with metal artifact reducing sequences has shown good results in detecting pseudotumors. The aim of this study is to survey a significant correlation among MRI findings, serum metal levels, and clinical scores in patients with small-head MOM implants and if serum cobalt and chromium levels are sufficient in detecting patients with pseudotumors in the long-term follow-up. METHODS: At a minimum follow-up of 20 years, 26 patients (29 THAs) of the original 98 patients (105 THAs) included in this study between November 1992 and May 1994 were available for follow-up examination. Clinical scores, serum metal ion levels, and MRIs were obtained. RESULTS: We found mean serum cobalt levels of 1.87 µg/L (±3.44) and chromium levels of 2.23 µg/L (±2.96) and very good clinical and functional results (mean Harris Hip Score 88.6) in the long-term follow-up. Pseudotumors were detected in MRIs of 21 hips. There were no significant differences between patients with or without pseudotumors regarding serum metal levels and the correlation for clinical outcome scores, demographic data, and cup inclination. The cumulative rate of survival was still at 91.4% at 22.8 years. CONCLUSION: This study presents the first published data on small-head MOM hips, comparing metal ion levels, pseudotumors, clinical, and radiological results in a follow-up period of more than 20 years and reveals that serum metal levels are not significantly higher in patients with pseudotumors. LEVEL OF EVIDENCE: Therapeutic Level III.


Assuntos
Artroplastia de Quadril , Prótese de Quadril , Próteses Articulares Metal-Metal , Artroplastia de Quadril/efeitos adversos , Cromo , Cobalto , Seguimentos , Prótese de Quadril/efeitos adversos , Humanos , Próteses Articulares Metal-Metal/efeitos adversos , Desenho de Prótese
5.
J Mech Behav Biomed Mater ; 118: 104435, 2021 06.
Artigo em Inglês | MEDLINE | ID: mdl-33721771

RESUMO

Cementless total knee arthroplasty (TKA) implants rely on interference fit to achieve initial stability. However, the optimal interference fit is unknown. This study investigates the effect of using different interference fit on the initial stability of tibial TKA implants. Experiments were performed on human cadaveric tibias using a low interference fit of 350 µm of a clinically established cementless porous-coated tibial implant and a high interference fit of 700 µm. The Orthoload peak loads of gait and squat were applied to the specimens with a custom-made load applicator. Micromotions and gaps opening/closing were measured at the bone-implant interface using Digital Image Correlation (DIC) in 6 regions of interest (ROIs). Two multilevel linear mixed-effect models were created with micromotions and gaps as dependent variables. The results revealed no significant differences for micromotions between the two interference fits (gait p = 0.755, squat p = 0.232), nor for gaps opening/closing (gait p = 0.474, squat p = 0.269). In contrast, significant differences were found for the ROIs in the two dependent variables (p < 0.001), where more gap closing was seen in the posterior ROIs than in the anterior ROIs during both loading configurations. This study showed that increasing the interference fit from 350 to 700 µm did not influence initial stability.


Assuntos
Artroplastia do Joelho , Prótese do Joelho , Interface Osso-Implante , Marcha , Humanos , Próteses e Implantes , Desenho de Prótese , Tíbia/cirurgia
6.
Proteomics Clin Appl ; 15(2-3): e2000057, 2021 05.
Artigo em Inglês | MEDLINE | ID: mdl-33580901

RESUMO

PURPOSE: N-Glycan profiling provides an indicator of the cellular potential for functional pairing with tissue lectins. Following the discovery of galectin expression by chondrocytes as a factor in osteoarthritis pathobiology, mapping of N-glycans upon their phenotypic dedifferentiation in culture and in fibroblast-like synoviocytes is a step to better understand glycobiological contributions to disease progression. EXPERIMENTAL DESIGN: The profiles of cellular N-glycans of human osteoarthritic chondrocytes and fibroblast-like synoviocytes were characterized by mass spectrometry. RT-qPCR experiments determined mRNA levels of 16 glycosyltransferases. Responsiveness of cells to galectins was quantified by measuring the mRNA level for interleukin-1ß. RESULTS: The shift of chondrocytes to a fibroblastic phenotype (dedifferentiation) is associated with changes in N-glycosylation. The N-glycan profile of chondrocytes at passage 4 reflects characteristics of synoviocytes. Galectins-1 and -3 enhance expression of interleukin-1ß mRNA in both cell types, most pronounced in primary culture. Presence of interleukin-1ß leads to changes in sialylation in synoviocytes that favor galectin binding. CONCLUSIONS AND CLINICAL RELEVANCE: N-Glycosylation reflects phenotypic changes of osteoarthritic cells in vitro. Like chondrocytes, fibroblast-like synoviocytes express N-glycans that are suited to bind galectins, and these proteins serve as inducers of pro-inflammatory markers in these cells. Synoviocytes can thus contribute to disease progression in osteoarthritis in situ.


Assuntos
Glicômica
7.
Int Orthop ; 45(4): 837-846, 2021 04.
Artigo em Inglês | MEDLINE | ID: mdl-33247312

RESUMO

PURPOSE: Besides other diagnostic test methods, established serum inflammatory markers such as serum C-reactive protein or leukocyte count are widely used preoperatively to aid in diagnosing periprosthetic joint infections (PJI). Although low accuracies were reported, these parameters are easily accessible and routinely available. Novel biomarkers with promising results in diagnosing PJI (platelet count to mean platelet volume ratio) or other infectious conditions (percentage of neutrophils, neutrophils to lymphocytes ratio) were described. The purpose of this study was to investigate the diagnostic value of established and novel serum inflammatory biomarkers for the diagnosis of PJI so as to compare the results to find the serum inflammatory marker with the best performance. METHODS: In 177 patients with a previous total hip (n = 91) or knee (n = 86) arthroplasty and indicated revision surgery, the diagnostic value of the routinely available serum inflammatory markers C-reactive protein (CRP), white blood cell count (WBC), percentage of neutrophils (%N), neutrophils to lymphocytes ratio (NLR), fibrinogen and platelet count to mean platelet volume ratio (PC/mPV) were examined retrospectively via receiver operating characteristic curve analysis (AUC). The curves were compared using the z-test. RESULTS: Sensitivities of serum CRP, WBC, %N, NLR, fibrinogen and PC/mPV were calculated with 68%, 36%, 66%, 63%, 69% and 43%, respectively. Specificities were 87%, 89%, 67%, 73%, 89% and 81%, respectively. Serum CRP (0.78) and fibrinogen (0.79) showed significantly better AUCs compared with serum WBC (0.63), %N (0.67), NLR (0.68) and PC/mPV (0.62) (p < 0.0001). Patients with PJI caused by a low-virulent microorganism (median CRP: 17.6 mg/L) obtained lower CRP levels compared with infections caused by high-virulent microorganisms (median CRP: 49.2 mg/L; p = 0.044). The combination of CRP and fibrinogen showed a better sensitivity (77%) with similar specificity (83%) than one method alone but not at a significant level (CRP (p = 0.200); fibrinogen (p = 0.437)). CONCLUSION: Serum CRP and fibrinogen showed the best accuracies among these widely available serum inflammatory parameters. However, due to the insufficient performance, these biomarkers can only be recommended as suggestive criteria in diagnosing PJI. The preoperative workup should always be complemented by more specific tests such as synovial fluid analysis.


Assuntos
Artroplastia de Quadril , Infecções Relacionadas à Prótese , Artroplastia de Quadril/efeitos adversos , Biomarcadores , Sedimentação Sanguínea , Proteína C-Reativa/análise , Humanos , Infecções Relacionadas à Prótese/diagnóstico , Infecções Relacionadas à Prótese/cirurgia , Estudos Retrospectivos , Sensibilidade e Especificidade , Líquido Sinovial/química
8.
J Mech Behav Biomed Mater ; 113: 104189, 2021 01.
Artigo em Inglês | MEDLINE | ID: mdl-33158789

RESUMO

Cementless femoral total knee arthroplasty (TKA) components use a press-fit (referred to as interference fit) to achieve initial fixation. A higher interference fit could lead to a superior fixation, but it could also introduce more damage to the bone during implantation. The purpose of the current study was to investigate the effect of interference fit on the micromotions and gap opening/closing at the bone-implant interface. Experimental tests were performed in six pairs of cadaveric femurs implanted with femoral components using a low interference fit of 350 µm and a high interference fit of 700 µm. The specimens were subjected to the peak loads of gait and squat, based on the Orthoload dataset. Digital Image Correlation (DIC) was used to measure the micromotions and opening/closing in different regions of interest (ROIs). Two linear mixed-effect statistical models were created with micromotions and gap opening/closing as dependent variables. ROIs, loading conditions, and implant designs as independent variables, and cadaver specimens as random intercepts. The results revealed no significant difference between the two interference fit implants for micromotions (p = 0.837 for gait and p = 0.065 for squat), nor for the gap opening/closing (p = 0.748 for gait and p = 0.561 for squat). In contrast, significant differences were found between loading and most of the ROIs in both dependent variables (p < 0.0001). Additionally, no difference in bone deformation was found between low and high interference fit. Changing interference between either 350 µm or 700 µm did not affect the primary stability of a femoral TKA component. There could be an interference fit threshold beyond which fixation does not further improve.


Assuntos
Artroplastia do Joelho , Prótese de Quadril , Interface Osso-Implante , Fêmur/cirurgia , Marcha , Humanos , Próteses e Implantes , Desenho de Prótese
9.
J Clin Med ; 9(7)2020 Jul 07.
Artigo em Inglês | MEDLINE | ID: mdl-32645917

RESUMO

Optimal osseointegration of cementless total hip arthroplasty is essential for high stability and long-term survival. The purpose of this follow-up study was to evaluate the clinical and radiological outcome, the complications, and survival rates of a beta-titanium alloy stem with a specific grit-blasted-free surface. In 192 patients (mean age of 64.4 years), 202 consecutive primary total hip arthroplasties were performed using a cementless Hipstar® stem (Stryker, Duisburg, DE). The Harris Hip Score (HHS) was assessed pre-operatively and post-operatively. Radiolucent lines were evaluated and the implant survival rate was calculated using Kaplan-Meier analysis. The mean follow-up was 7.71 years (range of 5.0-14.0 years). Overall, 15 revisions were performed. Early aseptic stem loosening was observed in six cases (2.97%). Radiolucent-lines adjacent to the stem were detected in 73 cases (83.02%), especially (70.46%) in the Gruen zones 1, 7, 8, and 14. The mean postoperative HHS was 92.65 points (range 42-100). The cumulative survival probability of the stem was 94.4% (95% CI 90.3 to 98.5%). Considering aseptic failure as an endpoint, the cumulative survival rate of the stem was 95.3% (95% CI 0.914 to 0.992) at six years of follow-up. Overall, an inferior mid-term implant survival was observed in comparison to well-established cementless stem designs.

10.
J Clin Med ; 9(6)2020 May 27.
Artigo em Inglês | MEDLINE | ID: mdl-32471214

RESUMO

The purpose of this study is to compare computer-assisted to manual implantation-techniques in total hip arthroplasty (THA) and to find out if the computer-assisted surgery is able to improve the clinical and functional results and reduce the dislocation rate in short-terms after THA. We performed a concise minimum 2-year follow-up of the patient cohort of a prospective randomized study published in 2014 and evaluated if the higher implantation accuracy in the navigated group can be seen as an important determinant of success in total hip arthroplasty. Although a significant difference was found in mean postoperative acetabular component anteversion and in the outliers regarding inclination and anteversion (p < 0.05) between the computer-assisted and the manual-placed group, we could not find significant differences regarding clinical outcome or revision rates at 2-years follow-up. The implantation accuracy in the navigated group can be regarded as an important determinant of success in THA, although no significant differences in clinical outcome could be detected at short-term follow-up. Therefore, further long-term follow-up of our patient group is needed.

11.
Front Physiol ; 9: 679, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-29922175

RESUMO

Introduction: New vessel formation requires a continuous and tightly regulated interplay between endothelial cells with cells of the perivascular microenvironment supported by mechanic-physical and chemical cues from the extracellular matrix. Aim: Here we investigated the potential of small fragments of synovial tissue to form de novo vascular structures in the context of inflammation within three dimensional (3D) fibrin-based matrices in vitro, and assessed the contribution of mesenchymal stromal cell (MSC)-immune cell cross-talk to neovascularization considering paracrine signals in a fibrin-based co-culture model. Material and Methods: Synovial tissue fragments from patients with rheumatoid arthritis (RA) and inflammatory osteoarthritis (OA) were cultivated within 3D fibrin matrices for up to 4 weeks. Cellular and structural re-arrangement of the initially acellular matrix were documented by phase contrast microscopy and characterized by confocal laser-scanning microscopy of topographically intact 3D cultures and by immunohistochemistry. MSC-peripheral blood mononuclear cell (PBMC) co-cultures in the 3D fibrin system specifically addressed the influence of perivascular cell interactions to neo-vessel formation in a pro-inflammatory microenvironment. Cytokine levels in the supernatants of cultured explant tissues and co-cultures were evaluated by the Bio-Plex cytokine assay and ELISA. Results: Vascular outgrowth from the embedded tissue into the fibrin matrix was preceded by leukocyte egress from the tissue fragments. Neo-vessels originating from both the embedded sample and from clusters locally formed by emigrated mononuclear cells were consistently associated with CD45+ leukocytes. MSC and PBMC in co-culture formed vasculogenic clusters. Clusters and cells with endothelial phenotype emerging from them, were surrounded by a collagen IV scaffold. No vascular structures were observed in control 3D monocultures of PBMC or MSC. Paracrine signals released by cultured OA tissue fragments corresponded with elevated levels of granulocyte-colony stimulating factor, vascular endothelial growth factor and interleukin-6 secreted by MSC-PBMC co-cultures. Conclusion: Our results show that synovial tissue fragments with immune cell infiltrates have the potential to form new vessels in initially avascular 3D fibrin-based matrices. Cross-talk and cluster formation of MSC with immune cells within the 3D fibrin environment through self-organization and secretion of pro-angiogenic paracrine factors can support neo-vessel growth.

12.
J Knee Surg ; 31(5): 467-471, 2018 May.
Artigo em Inglês | MEDLINE | ID: mdl-28701006

RESUMO

The primary objective was to compare the intraoperative data assessed by OrthoPilot (Aesculap AG, Tuttlingen, Germany) with postoperative coronal and sagittal long-leg standing radiographs. The secondary objective was to evaluate the influence of sex and body mass index (BMI) on the accuracy and effectiveness of the implantation of the knee prosthesis by OrthoPilot. We included 75 patients in our investigation. Participants received an e.motion (Aesculap AG) knee prosthesis using the OrthoPilot navigation system. Postoperative long-leg standing anteroposterior and lateral radiographs were performed. We compared the intraoperative navigational data with postoperative determined angles of knee geometry. We also compared the sex and BMI of participants to their difference between intraoperative and postoperative measurements to test for an association. We found a difference between intraoperative data and radiographs of 1.8 degrees for the hip-knee-ankle angle. The intraoperative lateral distal femoral angle and medial proximal tibial angle differed from the radiological analysis by 1.2 degrees, respectively. The lateral views revealed a difference of 1.6 degrees for femur lateral and 1.4 degrees for the tibia lateral. There was no significant (p > 0.05) influence of the parameters BMI and sex of the patients on these values. Our results showed that the implemented intraoperative navigation system is reliable. It does not differ on average from postoperative radiographs by more than 1.8 degrees. The findings of our study suggest that a correct postoperative alignment can be achieved in both high and low BMI participants if a precise range is maintained during the surgery.


Assuntos
Artroplastia do Joelho/métodos , Fêmur/diagnóstico por imagem , Prótese do Joelho , Cirurgia Assistida por Computador/métodos , Tíbia/diagnóstico por imagem , Adulto , Idoso , Idoso de 80 Anos ou mais , Pesos e Medidas Corporais , Feminino , Fêmur/cirurgia , Humanos , Masculino , Pessoa de Meia-Idade , Postura , Radiografia , Amplitude de Movimento Articular , Reprodutibilidade dos Testes , Estudos Retrospectivos , Tíbia/cirurgia , Suporte de Carga
13.
Biomed Res Int ; 2017: 7532745, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-29376075

RESUMO

BACKGROUND: In the current study, we investigated midterm results of a new rotating hinge total knee arthroplasty (EnduRo prosthesis), which uses a new bearing material (CFR PEEK). METHODS: We prospectively analysed data of 50 patients with a minimum follow-up of 5 years. In 24 (48%) patients, a primary implantation was performed and 26 (52%) were revision cases. Clinical and radiographic examinations were performed preoperatively as well as postoperatively after 3 and 12 months and annually thereafter. The Knee Society Score (KSS), WOMAC, Oxford Knee Score (OKS), and range of motion (ROM) were used for clinical assessment. RESULTS: KSS, WOMAC, OKS, and ROM significantly improved between the preoperative and the follow-up investigations. The overall survival rate with revision for any reason as an endpoint was 77.9% after five years. The number of complications was significantly higher in the revision group (p = 0.003). CONCLUSION: The EnduRo prosthesis provides highly satisfying clinical and functional results in severe primary as well as in revision cases. Implant-associated complications were rare. However, in cases of revision surgery, the risk for complications was considerably high, mostly related to previous joint infections and poor soft tissue quality.


Assuntos
Artroplastia do Joelho/métodos , Artroplastia do Joelho/estatística & dados numéricos , Articulação do Joelho/cirurgia , Prótese do Joelho/estatística & dados numéricos , Idoso , Feminino , Seguimentos , Humanos , Masculino , Complicações Pós-Operatórias/fisiopatologia , Estudos Prospectivos , Desenho de Prótese/métodos , Falha de Prótese , Amplitude de Movimento Articular/fisiologia , Reoperação/métodos , Taxa de Sobrevida , Resultado do Tratamento
14.
Biomed Res Int ; 2016: 7032830, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-28101512

RESUMO

Carbon fiber reinforced poly-ether-ether-ketone (CFR-PEEK) represents a promising alternative material for bushings in total knee replacements, after early clinical failures of polyethylene in this application. The objective of the present study was to evaluate the damage modes and the extent of damage observed on CFR-PEEK hinge mechanism articulation components after in vivo service in a rotating hinge knee (RHK) system and to compare the results with corresponding components subjected to in vitro wear tests. Key question was if there were any similarities or differences between in vivo and in vitro damage characteristics. Twelve retrieved RHK systems after an average of 34.9 months in vivo underwent wear damage analysis with focus on the four integrated CFR-PEEK components and distinction between different damage modes and classification with a scoring system. The analysis included visual examination, scanning electron microscopy, and energy dispersive X-ray spectroscopy, as well as surface roughness and profile measurements. The main wear damage modes were comparable between retrieved and in vitro specimens (n = 3), whereby the size of affected area on the retrieved components showed a higher variation. Overall, the retrieved specimens seemed to be slightly heavier damaged which was probably attributable to the more complex loading and kinematic conditions in vivo.


Assuntos
Artroplastia do Joelho , Carbono/efeitos adversos , Análise de Falha de Equipamento , Cetonas/efeitos adversos , Prótese do Joelho/efeitos adversos , Polietilenoglicóis/efeitos adversos , Desenho de Prótese/efeitos adversos , Falha de Prótese/efeitos adversos , Idoso , Benzofenonas , Fibra de Carbono , Feminino , Humanos , Polímeros
15.
Biomed Res Int ; 2014: 948520, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-25089279

RESUMO

BACKGROUND: Indication for rotating hinge (RH) total knee arthroplasty (TKA) includes primary and revision cases, with contradictory results. The aim of this study was to report prospective early results of a new modular rotating hinge TKA (EnduRo). For this implant several new design features and a new bearing material (carbon-fiber reinforced poly-ether-ether-ketone) have been developed. Furthermore, we tried to establish a new classification of failure modes for revision TKA. METHODS: 152 EnduRo rotating-hinge prostheses were implanted in two centers. In 90 patients a primary implantation has been performed and 62 patients were revision cases. Knee Society Score (KSS), Western Ontario and McMaster Osteoarthritis Index (WOMAC), Oxford Knee Score (OKS), and Range of motion (ROM) were assessed before surgery, 3 months postoperatively, 12 months postoperatively, and annually thereafter. We defined 3 types of complications: Type 1, infection; type 2, periprosthetic complications; type 3, implant failures. RESULTS: KSS, WOMAC, OKS, and ROM revealed significant improvements between the preoperative and the follow-up investigations. There were 14 complications (9.2%) leading to revision surgery, predominantly type 2. CONCLUSION: Our study shows excellent clinical results of the EnduRo TKA. Furthermore, no premature material failure or unusual biological response to the new bearing material could be detected.


Assuntos
Artralgia/prevenção & controle , Artroplastia do Joelho/instrumentação , Artroplastia do Joelho/métodos , Instabilidade Articular/diagnóstico , Instabilidade Articular/cirurgia , Prótese do Joelho , Idoso , Idoso de 80 Anos ou mais , Artralgia/diagnóstico , Artralgia/etiologia , Análise de Falha de Equipamento , Alemanha , Humanos , Instabilidade Articular/complicações , Pessoa de Meia-Idade , Projetos Piloto , Desenho de Prótese , Amplitude de Movimento Articular , Rotação , Resultado do Tratamento
16.
J Orthop Res ; 32(9): 1234-40, 2014 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-24841922

RESUMO

Diagnosis of adverse reactions to metal debris in metal-on-metal hip arthroplasty is a multifactorial process. Systemic ion levels are just one factor in the evaluation and should not be relied upon solely to determine the need for revision surgery. Furthermore, the correlation between cobalt or chromium serum, urine, or synovial fluid levels and adverse local tissue reactions is still incompletely understood. The hypothesis was that elevated serum and urine metal-ion concentrations are associated with elevated local metal-ion concentrations in primary total hip arthroplasties (THA) and with failure of metal-on-metal articulations in the long-term. In our present study, we evaluated these concentrations in 105 cementless THA with metal-on-metal articulating surfaces with small head diameter at a minimum of 18 years postoperatively. Spearman correlation showed a high correlation between the joint fluid aspirate concentration of cobalt and chromium with the serum cobalt (r = 0.81) and chromium level (r = 0.77) in patients with the THA as the only source of metal-ions. In these patients serum metal-ion analysis is a valuable method for screening. In patients with more than one source of metal or renal insufficiency additional investigations, like joint aspirations are an important tool for evaluation of wear and adverse tissue reactions in metal-on-metal THA.


Assuntos
Artroplastia de Quadril/instrumentação , Cromo/metabolismo , Cobalto/metabolismo , Prótese de Quadril , Líquido Sinovial/metabolismo , Idoso , Idoso de 80 Anos ou mais , Cromo/sangue , Cromo/urina , Cobalto/sangue , Cobalto/urina , Estudos Transversais , Análise de Falha de Equipamento , Feminino , Seguimentos , Articulação do Quadril/cirurgia , Humanos , Estudos Longitudinais , Masculino , Pessoa de Meia-Idade , Desenho de Prótese , Resultado do Tratamento
17.
Int Orthop ; 38(8): 1597-602, 2014 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-24817024

RESUMO

PURPOSE: The purpose of our study was to evaluate and quantify the bacterial adherence to the different components of total hip prosthesis. METHODS: The bacterial load of 80 retrieved hip components from 24 patients was evaluated by counting of colony-forming units (CFU) dislodged from component surfaces using the sonication culture method. RESULTS: Micro-organisms were detected in 68 of 80 explanted components. The highest bacterial load was detected on the polyethylene liners, showing a significant difference in distribution of CFU between the liner and metal components (stem and cup). Staphylococcus epidermidis was identified as the pathogen causing the highest CFU count, especially from the polyethylene liner. CONCLUSIONS: Results of our study confirm that sonicate culture of the retrieved liners and heads, which revealed the highest bacterial loads, are reliable and sufficient for pathogen detection in the clinical diagnostic routine.


Assuntos
Artroplastia de Quadril/instrumentação , Aderência Bacteriana , Prótese de Quadril/microbiologia , Infecções Relacionadas à Prótese/epidemiologia , Adulto , Idoso , Idoso de 80 Anos ou mais , Técnicas de Cultura de Células/métodos , Contagem de Colônia Microbiana , Feminino , Humanos , Incidência , Masculino , Pessoa de Meia-Idade , Infecções Relacionadas à Prótese/diagnóstico , Infecções Relacionadas à Prótese/microbiologia , Reprodutibilidade dos Testes , Estudos Retrospectivos , Sonicação/métodos , Staphylococcus epidermidis/isolamento & purificação
18.
J Arthroplasty ; 29(4): 786-91, 2014 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-24290738

RESUMO

In a prospective randomized study of two groups of 65 patients each, we compared the acetabular component position when using the imageless navigation system compared to the freehand conventional technique for cementless total hip arthroplasty. The position of the component was determined postoperatively on computed tomographic scans of the pelvis. There was no significant difference for postoperative mean inclination (P = 0.29), but a significant difference for mean postoperative acetabular component anteversion (P = 0.007), for mean deviation of the postoperative anteversion from the target position of 15° (P = 0.02) and for the outliers regarding inclination (P = 0.02) and anteversion (P < 0.05) between the computer-assisted and the freehand-placement group. Our results demonstrate the importance of imageless navigation for the accurate positioning of the acetabular component.


Assuntos
Acetábulo/diagnóstico por imagem , Artroplastia de Quadril/métodos , Prótese de Quadril , Cirurgia Assistida por Computador , Acetábulo/cirurgia , Adulto , Idoso , Idoso de 80 Anos ou mais , Anteversão Óssea/diagnóstico por imagem , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Tomografia Computadorizada por Raios X
19.
Int Orthop ; 38(4): 703-9, 2014 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-24114250

RESUMO

PURPOSE: The failure of total hip systems caused by wear-particle-induced loosening has focused interest on factors potentially affecting wear rate. Remnants of the blasting material were reported on grit-blasted surfaces for cementless fixation. These particles are believed to cause third-body wear and implant loosening. The purpose of this study was to evaluate the early clinical and radiological outcomes of a cementless hip system with a new, contamination-free, roughened surface with regard to prosthesis-related failures. METHODS: Between May 2004 and March 2009, 202 consecutive primary total hip arthroplasties (THAs) (192 patients with a mean age of 62.6 years) were performed using a cementless stem (Hipstar®) and a hemispherical acetabular cup (Trident®). RESULTS: At a minimum follow-up of two years, five revisions (2.5%) due to aseptic loosening of the stem and three (1.5%) of the cup were necessary. The cumulative rate of prostheses survival, counting revision of both components and with aseptic failure as end point, was 92.9% at 8.8 years. Radiolucent lines up to three millimetres were evaluated in the proximal part of the femur in 61% of cases. CONCLUSIONS: Although the incidence of radiolucent lines was decreased, the revision rate was considerably increased compared to other uncemented hip implants with grit-blasted surfaces in the short- to mid-term follow-up of our study. Subsequent studies are needed to confirm whether these changes in implant material and surface affect the radiological and clinical outcome in the long term.


Assuntos
Artroplastia de Quadril , Prótese de Quadril , Osseointegração , Desenho de Prótese , Adulto , Idoso , Idoso de 80 Anos ou mais , Cimentação , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Falha de Prótese , Reoperação
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...